WARD Adenosine Cardiac Stress Scintigraphy

WARD Adenosine Cardiac Stress Scintigraphy

Study design
Prospective study/cohort
Sample size
100 participants
Study sites

Rigshospitalet

Inclusion criteria
  • Adults referred for rubidium-82 PET/CT cardiac stress imaging because of suspected reduced blood supply to the heart, including preoperative assessments.
Study procedures

Researchers simultaneously recorded a wearable single-lead ECG and standard 12-lead ECG before and during a six-minute adenosine stress test, comparing changes in the ST segment.

Results
A total of 110 patients were included during the study period and 17 were excluded, 14 because of poor quality of the signal leading to dissatisfactory matching between ECG methods and three due to interrupted scan sequences, leaving 93 patients for analysis. Mean age was 63 years (SD 10.7) with an average BMI of 29, and30.07% were women (31 patients). The most frequent co-morbidities were diabetes in 58 patients, hypertension in 22, and 20 were diagnosed with ischemic cardiac disease before the scan.
Totals of 26 h of 12-lead ECG and 31 h of single-lead ECG were recorded counting all patients included, with an average of 16.2 min of continuous recording per patient on the 12-lead ECG and 20.2 min of continuous recording per patient on the single-lead ECG.
After matching of the recordings on heart rate, interpolation, and exclusion of data according to exclusion criteria, we had a total of 93 datapoints corresponding to the maximum value of the rolling mean for each patient.
Outcome

Single-lead and standard ECG measurements agreed within the study’s predefined criteria for ST-segment changes, but individual differences were substantial. The study suggests potential for monitoring and does not establish equivalence to a diagnostic 12-lead ECG.

Trial registration
No trial registration. Publication:

–  Read more